Combi Flash 7650 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Carrinhos de bebé Combi Flash 7650 Series. Combi Flash 7650 Series User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 159
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
i
CombiFlash Tor re n t
®
User Manual
For indoor use only
COPYRIGHT © 2009 by
Teledyne Isco
4700 Superior St., Lincoln, Nebraska, U.S.A. 68504
Phone: (402) 464-0231
Toll Free: (800) 228-4373
FAX: (402) 465-3022
Revision E, August 13, 2013
Part #60-5243-135
Vista de página 0
1 2 3 4 5 6 ... 158 159

Resumo do Conteúdo

Página 1 - User Manual

iCombiFlash Tor re n t®User ManualFor indoor use onlyCOPYRIGHT © 2009 byTeledyne Isco4700 Superior St., Lincoln, Nebraska, U.S.A. 68504Phone: (402) 46

Página 2

CombiFlash Torrent® User Manual1-41.4 SpecificationsTable 1-1 CombiFlash Torrent Module Specifications1Sample size: 0.5 to 300 gramsRediSep Rf column

Página 3

CombiFlash Torrent® User Manual4-204.3.2.6 Peak DetectionThis section of the window contains option buttons to enable and disable various peak detect

Página 4 - 4. User Help Reference

Section 4 User Help Reference4-21Note: If both Slope and Threshold peak detection methods are checked, PeakTrak considers a peak to be present when a

Página 5 - 5. Remote Interfaces

CombiFlash Torrent® User Manual4-22To open the Gradient Optimizer window, open the METHOD EDITOR [4.3.2] window, then click the Gradient Optimizer but

Página 6 - 6. Maintenance

Section 4 User Help Reference4-23command to prevent the original file from being overwritten.• Delete — Click this button to delete a highlighted fil

Página 7

CombiFlash Torrent® User Manual4-244.3.6 Set Data PathThe FILE>SET DATA PATH… [4.2.1.4] menu command opens the Set Data Path window. Use this wind

Página 8

Section 4 User Help Reference4-25• Progress bar — This bar displays how much of the solvent has been pumped. • Play button — Click this button to sta

Página 9 - 1.3 Operating Overview

CombiFlash Torrent® User Manual4-26• Flow Rate – Type or select the pump’s flow rate in mL/min.• Pump into Tube # – As a default setting, solvent is p

Página 10 - 1.4 Specifications

Section 4 User Help Reference4-27by selecting the TOOLS>MANUAL CONTROL [4.2.3.3] menu command.The configuration window displays four tabs: INSTRUM

Página 11 - Section 1 Introduction

CombiFlash Torrent® User Manual4-28• Enable solvent B priming pump — The CombiFlash Torrent module is equipped with a priming pump for the B solvent t

Página 12

Section 4 User Help Reference4-29volume. During a run, other factors such as automatic tube advances for detected peaks will affect collected volume.

Página 13

Section 1 Introduction1-51.5 Controls, Indicators, and FeaturesFigures 1-1 through 1-3 illustrate key features on the Torrent.Figure 1-1 CombiFlash

Página 14

CombiFlash Torrent® User Manual4-30Follow the on-screen instructions for entering the address and queue information. After successfully printing a tes

Página 15 - 1.6 Safety

Section 4 User Help Reference4-31the programmed run length. This ensures that a late-eluting peak is still collected.Gradient Method Select the desir

Página 16

CombiFlash Torrent® User Manual4-32A delay volume must also be specified for each Foxy fraction collector connected as a system. If using the Fraction

Página 17

Section 4 User Help Reference4-333.To protect the Default methods select the “Require Password For Editing Default Methods” option.4.Click the OK but

Página 18 - Symboles de sécurité

CombiFlash Torrent® User Manual4-34•MONITORING THE WAVELENGTH RATIO [4.4.7]•BYPASSING THE SOLID LOAD CARTRIDGE [4.4.8]•VIEWING RUNS [4.4.9]•MANUAL CON

Página 19 - Advertencias y Precauciones

Section 4 User Help Reference4-35equilibration and then wait while you prepare the cartridge. After you have placed the cartridge on the module, clic

Página 20

CombiFlash Torrent® User Manual4-36If you selected Solid (Pause), the module equilibrates the column with the starting %B and then waits while you pre

Página 21

Section 4 User Help Reference4-37If you will transfer the sample mixture directly from a container, attach the tubing to the pump inlet. Next, place

Página 22 - 2.3 Connect Power

CombiFlash Torrent® User Manual4-384.4.2.1 Basic method settingsThe basic settings allow you to control the %B gradient mix, flow rate, solvents, and

Página 23 - NSTALL OPTIONAL EQUIPMENT

Section 4 User Help Reference4-39• RediSep Rf 3 kg = 4.8 LOther media types will have similar column volumes. Refer to the REDISEP RF COLUMN SELECTIO

Página 24 - 2.5 Position the Torrent

CombiFlash Torrent® User Manual1-61. Touch Panel LCD display – Large 10.4 inch display for system monitoring and control.2. On/Standby Switch – 1 = On

Página 25 - 2.6 Connect Solvent Lines

CombiFlash Torrent® User Manual4-40When using the All or Peaks options, you can specify the maximum Peak and Non-peak volumes to be collected in the t

Página 26 - (Solvent B)

Section 4 User Help Reference4-41• Peak Width — Select the average peak width setting. Peak widths are measured at the baseline. The slope detector w

Página 27 - 2 turn using a wrench

CombiFlash Torrent® User Manual4-42the External Detector instruction sheet for electrical and plumbing requirements.• Show Ratio — If using two of the

Página 28 - 8-inch fittings from the

Section 4 User Help Reference4-43save the method using the FILE>Save or Save As menu commands.4.4.3.3 Scaling Method Files to Different Column Si

Página 29

CombiFlash Torrent® User Manual4-44button. The settings will revert to the original factory settings. Click the Save button to save the settings for f

Página 30

Section 4 User Help Reference4-454.4.7 Monitoring the Wavelength RatioWhen using two peak detection options, such as 1 with 2 or All Wavelength De

Página 31 - 2.8 Optional External Gas

CombiFlash Torrent® User Manual4-46CAUTION: Bypassing the solid load cartridge too soon during the purification run may leave desired compounds on the

Página 32

Section 4 User Help Reference4-47TLC, wait at least the time established as T. After this time has elapsed it is likely that the desired compound has

Página 33 - Drop Former (NC)

CombiFlash Torrent® User Manual4-48• Chromatogram — The right side of the window displays the chromatogram, identified by the Sample Name in the title

Página 34 - ETWORK CONFIGURATION

Section 4 User Help Reference4-49• Close button — Click the Close button when you are done viewing the run.4.4.9.1 General instructions for reading

Página 35 - Section 2 Preparation

Section 1 Introduction1-7media of choice. The cartridge outlet connects to the sample injection port (9).12.Solid Load Cartridge Cap – Adds the cartr

Página 36

CombiFlash Torrent® User Manual4-50module, first open the MANUAL CONTROL [4.3.9] window by selecting the Tools>Manual Control menu command.4.4.10.1

Página 37

Section 4 User Help Reference4-51for modules with flow cell windows stained by compounds.• Red – lamp energy is obstructed to a degree that the modul

Página 38

CombiFlash Torrent® User Manual4-52ambient environment of your laboratory. In this case, increase the setting of the Vapor Limit. Settings greater tha

Página 39

5-1CombiFlash To r re n t®User ManualSection 5 Remote InterfacesThis section provides instructions for controlling the CombiFlash Torrent module throu

Página 40

CombiFlash Torrent® User Manual5-26. Confirm that your network administrator has completed any necessary network changes to support the system. 7. Usi

Página 41

Section 5 Remote Interfaces5-3uses a JetDirect print queue, also ask for the port number. When this information is known, you can proceed with config

Página 42 - From top of diverter valve

CombiFlash Torrent® User Manual5-4(iPod Touch, iPhone, and iPad1) running iOS 4.2 or later. The PeakTrak app is available for download from the App St

Página 43 - Connect ELSD

Section 5 Remote Interfaces5-5NoteThe following instructions may require a user account with Administrator privileges on the PC. If you cannot modify

Página 44

CombiFlash Torrent® User Manual5-65.2.2 Windows Vista Settings1. From the Windows Start menu, right-click on Network, then select the Properties menu

Página 45 - Standoffs (place over

Section 5 Remote Interfaces5-7Figure 5-2 Internet Protocol Version 4 (TCP/IPv4) PropertiesNoteIf the Internet Protocol Version 4 (TCP/IPv4) option i

Página 46 - Disconnect

CombiFlash Torrent® User Manual1-816.Gas Inlet – The Torrent has an internal air pump that delivers air through the column for a post-run purge. The a

Página 47

CombiFlash Torrent® User Manual5-85.2.3 Windows XP Settings1. From the Windows Start button, open the Control Panel.2. Locate the Network Connection

Página 48 - 2.13 Configure the Torrent

Section 5 Remote Interfaces5-9Figure 5-4 Local Area Connection PropertiesFigure 5-5 Alternate Configuration Settings

Página 49

CombiFlash Torrent® User Manual5-105.2.4 Windows 2000 Settings1. From the Windows Start button, select “Settings>Control Panel” to view the contro

Página 50 - B priming pump

Section 5 Remote Interfaces5-11Figure 5-6 Local Area Connection Properties WindowFigure 5-7 Internet Protocol Properties Window

Página 51 - 2.13.2 User Preferences

CombiFlash Torrent® User Manual5-125.2.5 Completing the Direct Connection1. Connect the PC to the Torrent using the cross-over cable.2. Start Interne

Página 52 - EMOTE INTERFACES. Do not

6-1CombiFlash To r re n t®User ManualSection 6 Maintenance6.1 System Standby and Shut Down During extended periods of inactivity, you can place the s

Página 53

CombiFlash Torrent® User Manual6-26.2 Preventive MaintenanceThe system requires preventive maintenance by the user for safe and reliable operation. R

Página 54

Section 6 Maintenance6-36.3 CleaningTo clean the exterior surfaces, use a cleaning cloth dampened with a mixture of distilled water and a mild deter

Página 55

CombiFlash Torrent® User Manual6-46.4 Tubing InspectionWARNINGRisk of fire or equipment damage. Faulty tubing, fittings, and drains may allow organic

Página 56

Section 6 Maintenance6-5Figure 6-1 Default post-separation column and flow cell flushFigure 6-2 Flow cell cleaning messageTypically, chemists Stop

Página 57 - RIME B button

Section 1 Introduction1-9Figure 1-3 CombiFlash Torrent Features (Back)29.Cooling Fan – Cools the internal components.30.Ethernet Port – An 8P8C jack

Página 58

CombiFlash Torrent® User Manual6-6CAUTIONWhen using methanol as solvent B with silica column media, do not pump more than 50% solvent B. Higher percen

Página 59

Section 6 Maintenance6-7• Red – lamp energy is obstructed to a degree that the system might not reliably detect peaks. If you attempt to operate the

Página 60

CombiFlash Torrent® User Manual6-8NotePumping solvent B at a moderate flow rate (150 to 200 mL/min) over time will usually solubilize obstructions. Ge

Página 61

Section 6 Maintenance6-9Table 6-1 Suggested Flow Cell Cleaning SolventsaSolvent DescriptionMethanol Miscible with most LC solvents. Methanol will for

Página 62

CombiFlash Torrent® User Manual6-106.5.3 Monthly Flow Cell CleaningPerform this procedure as part of your scheduled preventive maintenance, or when Q

Página 63

Section 6 Maintenance6-116.6 Electrical TroubleshootingIf your instrument stops working and the touch panel display is off, check the line cord conn

Página 64

CombiFlash Torrent® User Manual6-12

Página 65 - Section 3 Operation

DECLARATION OF CONFORMITY Application of Council Directive: 2004/108/EC -The EMC Directive 2002/96/EC – The WEEE Directive 73/23/EEC –

Página 66 - 3.2 Sample Preparation

CombiFlash Hazmat Table 60-5233-406 Rev. B ℶ❐₼㦘㹡㦘⹂䓸德㒥⏒侯䤓⚜䱿♙⚺摞 Name and amount of Hazardous Substances or Elements in the product 捷ↅ⚜䱿 Compon

Página 68 - OOLS>MANUAL CONTROL)

CombiFlash Torrent® User Manual1-10WARNINGLiquids associated with this instrument may be classified as carcinogenic, biohazard, flammable, or radioact

Página 69

Section 1 Introduction1-111.6.1 Hazard Severity LevelsThis manual applies Hazard Severity Levels to the safety alerts. These three levels are descri

Página 70

CombiFlash Torrent® User Manual1-12Table 1-2 Hazard SymbolsWarnings and CautionsThe exclamation point within the triangle is a warning sign alerting y

Página 71 - 4 turn to seal the fittings

Section 1 Introduction1-131.7 For Additional InformationTechnical assistance for the Torrent can be obtained from:Teledyne Isco4700 Superior St.Linc

Página 72 - 3.4 Start a Default Method

CombiFlash Torrent® User ManualiiTeledyne Isco One Year Limited Warranty* Factory Service for Teledyne Isco CombiFlash® Systems This warranty exclusiv

Página 73

CombiFlash Torrent® User Manual1-14

Página 74 - 3.4.1 Syringe Injection

2-1CombiFlash To r re n t®User ManualSection 2 PreparationThis section provides instructions for unpacking and installing the CombiFlash Torrent modul

Página 75

CombiFlash Torrent® User Manual2-2Compare the contents of the boxes with the enclosed packing slips. If there are any shortages, contact Teledyne Isco

Página 76

Section 2 Preparation2-3quickly be removed from the outlet in the event of an emergency.CAUTIONUnless power must be removed due to an emergency, alwa

Página 77 - 3.5 During the Run

CombiFlash Torrent® User Manual2-42.4.4 Cabling: Network ConnectionThe Torrent can be added to a network or directly connected to a computer for remo

Página 78

Section 2 Preparation2-5CAUTIONEnsure that the CombiFlash Torrent has at least 3 cm (1.25") of air space behind it for ventilation.Determine whe

Página 79

CombiFlash Torrent® User Manual2-6NoteIf a System Verification (Section 2.15) will be performed, the required solvents are hexane (Solvent A) and ethy

Página 80

Section 2 Preparation2-7a. Locate a nut (60-0923-015) and ferrule (60-0083-163) in the accessory package (60-5249-002).b. Insert the ferrule, narrow

Página 81 - Section 4 User Help Reference

CombiFlash Torrent® User Manual2-82.6.3 Pressurized Solvent Lines in the LaboratoryWhen receiving solvent from pressurized lines on-site, the Torrent

Página 82 - 4.1.2 Method File

Section 2 Preparation2-9CAUTIONElevated flammable vapor levels are possible. Ensure that the waste container is adequately ventilated, preferably by

Página 83 - 4.2 PeakTrak Menu Options

iiiCombiFlash To r re n t®User ManualTable of Contents1. Introduction1.1 Documentation Overview . . . . . . . . . . . . . . . . . . . . . 1-11.2 Pro

Página 84 - 4.2.1.4 Set Data Path…

CombiFlash Torrent® User Manual2-10If using the optional Waste Outlet Cap (60-5394-512 for 83B closures, 60-5394-513 for 100 mm closures), proceed wit

Página 85 - [4.3.5] window. From

Section 2 Preparation2-11If an optional waste cap is not used, ensure the waste lines are secured so they drain into the waste container. Secure the

Página 86 - [4.2.1.9] menu command

CombiFlash Torrent® User Manual2-122.10 Install Optional EquipmentThe installation of optional equipment that was electrically connected to the Torre

Página 87 - [4.3.9]

Section 2 Preparation2-132.10.2 Optional Foxy R2 High Flow Fraction CollectorThe fraction collector(s) should be positioned to the right of the Torr

Página 88 - 4.2.3.8 User Management

CombiFlash Torrent® User Manual2-14• Use the supplied cable ties to secure the tubing as desired. Before turning on any fraction collector, manually m

Página 89

Section 2 Preparation2-15TCP/IP Settings in the Foxy R2The IP address and netmask are entered from the fraction collector front panel.1. Select Confi

Página 90 - 4.3 PeakTrak Windows

CombiFlash Torrent® User Manual2-16TCP/IP Settings in the TorrentThe network information for the Torrent is entered from the front panel.1. Select Too

Página 91 - 4.3.1.2 Run Settings

Section 2 Preparation2-17Torrent/Foxy R2 Network Configuration: ExamplesTypical examples of Torrent/Foxy R2 network connection are provided in this s

Página 92

CombiFlash Torrent® User Manual2-18In Example 2, the system runs on your network with each unit directly connected to your network.Figure 2-9 Network

Página 93

Section 2 Preparation2-19In Example 3, the system runs on your network with each unit connected to an Ethernet hub, and then to your network. The pas

Página 94 - 4.3.1.5 Peak Collection Data

CombiFlash Torrent® User Manualiv2.10.3 Optional Foxy R2 High Flow Fraction Collector . . . . . . . . . . . . . . . . . . . . . .2-142.10.4 Model 340

Página 95 - 4.3.2.1 Button bar

CombiFlash Torrent® User Manual2-202.10.3 Optional Fractionation ValveThe fractionation valve is an alternative to the typical Foxy fraction collecto

Página 96 - [4.3.10] settings

Section 2 Preparation2-212. Connect the supplied tubing between the Torrent’s TO COLLECTOR port and the Fractionation Valve’s diverter valve IN port

Página 97 - [ON-LINE]. The

CombiFlash Torrent® User Manual2-22Figure 2-14 Six-port valve connections123456Collection VesselsFromTorrentNormallyClosedCommonNormallyOpenWasteFrom

Página 98 - [4.4.5]

Section 2 Preparation2-232.10.4 Model 340CF Evaporative Light Scattering Detector (ELSD)The Torrent can be configured for use with Teledyne Isco’s 3

Página 99 - 4.3.2.5 Peak Collection

CombiFlash Torrent® User Manual2-24Plumbing the Torrent to the ELSD requires the connection package, part #60-5247-021. The package contains the follo

Página 100 - 4.3.2.6 Peak Detection

Section 2 Preparation2-252. Using the two long screws with lock and flat washers, mount the metal tee fitting on the rear panel, aligning the two sta

Página 101 - 4.3.3 Gradient Optimizer

CombiFlash Torrent® User Manual2-26Figure 2-18 Torrent: Disconnect tubing from bottom column connection5. Locate the black PTFE tubing that is swaged

Página 102 - [4.2.1.2] and SAVE

Section 2 Preparation2-27Figure 2-19 Tee fitting for Torrent to ELSD2.10.5 User-supplied External DetectorThe Torrent can be configured for use wit

Página 103 - [4.2.1.2]

CombiFlash Torrent® User Manual2-282.11 GroundingWARNINGRisk of fire or explosion. Nonconductive, nonpolar liquids at linear velocities greater than

Página 104 - [4.2.3.1] menu command. The

Section 2 Preparation2-29(sections 2.13.1 through 2.13.3) for the desired operation and then click OK to save the settings.Some configuration setting

Página 105 - [4.2.3.2] menu command. The

Table of Contentsv4.2 PeakTrak Menu Options . . . . . . . . . . . . . . . . . . . . . . 4-34.2.1 File . . . . . . . . . . . . . . . . . . . . . . .

Página 106 - [4.4.10]

CombiFlash Torrent® User Manual2-30level sensing feature (recommended). Otherwise, uncheck this option to disable this feature. Solvent B Priming Pump

Página 107 - [ON-LINE]

Section 2 Preparation2-31• Ensure that no open containers or spills of organic solvent are in close proximity to the Torrent.• Ensure that the Torren

Página 108 - [4.3.2.5] settings on the

CombiFlash Torrent® User Manual2-32Automatically Print Report at End of Run – if this option is enabled, the system will print a report at the end of

Página 109

Section 2 Preparation2-33NoteThe System Verification procedure (section 2.15) requires a Linear gradient method.Enable Run Length Extension – When en

Página 110 - ETWORK PRINTING feature

CombiFlash Torrent® User Manual2-34third extensions. At 24 minutes, the %B solvent strength returned to zero. Before the final minute elapsed, more co

Página 111 - 4.3.10.4 Fraction Collector

Section 2 Preparation2-35Foxy 3 Delay Volume – 60 mLFoxy 4 Delay Volume – 80 mLFractionation Valve Delay Volume – 10 mLIf using custom-length tubing,

Página 112 - 4.3.11 Set Password

CombiFlash Torrent® User Manual2-36CAUTIONExcept during an emergency, never remove AC power immediately after placing the Power switch in the Off posi

Página 113 - 4.3.12 User Management

Section 2 Preparation2-37NoteWhen pumping solvents the first time, inspect the solvent and waste connections to the system. If any leaks are observed

Página 114 - ON-LINE])

CombiFlash Torrent® User Manual2-38CAUTIONPinch point. Your fingers or hands can be seriously injured if you place them between the moving parts of th

Página 115

Section 2 Preparation2-3910.After equilibration, the Torrent will pause for sample injection. Draw 2 mL of the dissolved Test Mix B solution into a s

Página 116

CombiFlash Torrent® User Manualvi6. Maintenance6.1 System Standby and Shut Down . . . . . . . . . . . . . . . 6-16.2 Preventive Maintenance . . . . .

Página 117 - 4.4.2 Editing a method

CombiFlash Torrent® User Manual2-40Figure 2-22 Test Mix B Chromatogram: Peak 1=benzophenone; Peak 2=methyl 4-hydroxybenzoate; Peak 3=4-aminobenzoic a

Página 118 - [4.3.10] window

Section 2 Preparation2-41Table 2-1 Installation Qualification ChecklistStep DescriptionInstaller InitialsOperator Initials2.1UNPACKING THE UNIT2.2IN

Página 119 - [ON-LINE] for actual

CombiFlash Torrent® User Manual2-42

Página 120

3-1CombiFlash To r re n t®User ManualSection 3 OperationThis section provides abbreviated operating instructions for the CombiFlash Torrent module. Fo

Página 121

CombiFlash Torrent® User Manual3-2Figure 3-1 Changing column luer adaptersThe cartridge outlet (sample injection port) also has a fitting that can be

Página 122 - [4.2.1.9]

Section 3 Operation3-3Figure 3-2 Changing cartridge inlet and outlet adapters 3.1.2 Cartridge Inlet AdapterAn adapter is required when using 25 and

Página 123 - [4.4.2]

CombiFlash Torrent® User Manual3-4The Direct Injection Adapter is recommended when using the Liquid Load Pump to load samples directly on the column,

Página 124 - [4.3.1] and

Section 3 Operation3-53.2.1 Liquid Sample InjectionIf the sample is soluble in the starting mobile phase, it can be prepared as a solution and injec

Página 125 - [4.3.2] window

CombiFlash Torrent® User Manual3-6c. Agitate the solvent for a moment to allow the sample to adsorb to the silica.d. Remove the solvent with a suitabl

Página 126 - [4.3.3]). Note the

Section 3 Operation3-7Figure 3-3 Press the lever and extend the plunger3. Slide the plunger into the cartridge until it reaches the top frit (Figure

Página 127 - [4.3.1]

1-1CombiFlash To r re n t®User ManualSection 1 Introduction1.1 Documentation OverviewThis Installation Guide provides:• Safety Information• Unpacking

Página 128 - [4.3.10.2] settings

CombiFlash Torrent® User Manual3-8Figure 3-4 Insert the plunger to the bedFigure 3-5 Align and push cartridge into the cap, and then rotate the cart

Página 129 - [4.4.7] help topic

Section 3 Operation3-93.3 Loading a RediSep Rf ColumnTo load a RediSep Rf column:WARNINGThe CombiFlash Torrent has redundant safety devices to limit

Página 130 - [4.3.9] window by

CombiFlash Torrent® User Manual3-10NoteAfter loading a RediSep Rf column, the system will use RFID technology to automatically detect the media type a

Página 131 - [ON-LINE] topic

Section 3 Operation3-11cartridge. After you have placed the cartridge on the system, click OK to continue with the run. • Solid – Select this option

Página 132

CombiFlash Torrent® User Manual3-12•If you selected Solid (Pause), the system equilibrates the column with the starting %B solvent mixture and then wa

Página 133 - CombiFlash To r re n t

Section 3 Operation3-133. Open the valve.4. Inject the liquid sample mixture.5. Close the valve and remove the syringe.NoteChase solvent clears the L

Página 134 - 5.1.2 Network Printing

CombiFlash Torrent® User Manual3-14Figure 3-7 Sample Load Pump options2. Prepare the Sample Load pump to receive the sample.If the sample mixture wil

Página 135 - Section 5 Remote Interfaces

Section 3 Operation3-153.5 During the RunYou can monitor the progress of the run on the PeakTrak main window. If desired, you can modify gradient pa

Página 136 - 5.2 Direct Connection

CombiFlash Torrent® User Manual3-16CAUTIONWhen the Stop button is pressed, solvent remains in the tubing from the injection valve to the detector’s fl

Página 137

Section 3 Operation3-17NoteWhen you click the Next Tube button, the system immediately marks the tube advance on the chromatogram. However, the syste

Página 138 - 5.2.2 Windows Vista Settings

CombiFlash Torrent® User Manual1-2The Torrent is optimized for use with Teledyne Isco’s RediSep® Rf columns, which are pre-packed with a variety of me

Página 139

CombiFlash Torrent® User Manual3-18

Página 140 - 5.2.3 Windows XP Settings

4-1CombiFlash To r re n t®User ManualSection 4 User Help ReferenceThe CombiFlash Torrent module includes User Help topics that are available from the

Página 141

CombiFlash Torrent® User Manual4-2• Module Status — PeakTrak displays the module status to the right of the menu. Status messages may include:• The cu

Página 142 - 5.2.4 Windows 2000 Settings

Section 4 User Help Reference4-34.1.2.1 Default MethodsWhen PeakTrak is started, and every time you insert a RediSep Rf column, the module loads a d

Página 143

CombiFlash Torrent® User Manual4-4•TOOLS [4.2.3]•HELP [4.2.4]4.2.1 FileThe file menu lists the following commands:4.2.1.1 NewChoose the New command

Página 144 - 5.3 Direct Printing

Section 4 User Help Reference4-54.2.1.5 Save MethodChoose this menu command to save the settings of the current method file to the module’s internal

Página 145

CombiFlash Torrent® User Manual4-6drive. The file name will be the same as the Run file, except with a “TXT” file name extension. When selecting this

Página 146 - 6.2 Preventive Maintenance

Section 4 User Help Reference4-74.2.1.12 Print…From the touch screen, this command prints the completed run on the network printer (see NETWORK PRIN

Página 147 - 6.3 Cleaning

CombiFlash Torrent® User Manual4-84.2.3.4 Auto ZeroChoose this command to zero the absorbance trace during a run.4.2.3.5 Edit defaultsChoose this co

Página 148 - 6.5 Flow Cell Cleaning

Section 4 User Help Reference4-94.2.3.9 Calibrate TouchscreenChoose this command from the touch screen to calibrate the interaction between touch sc

Página 149 - Section 6 Maintenance

Section 1 Introduction1-31.3 Operating OverviewThe Torrent is equipped with a touch screen display for local control.The system supports TCP/IP comm

Página 150

CombiFlash Torrent® User Manual4-104.2.4.5 About PeakTrakChoose this command to view information about PeakTrak.4.2.4.6 About IscoChoose this comman

Página 151

Section 4 User Help Reference4-11the left side of the window changes to show a collection point map or the method parameters in a PEAK COLLECTION DAT

Página 152

CombiFlash Torrent® User Manual4-12• Sample Name — The sample name is a text entry box in which you can label the run. Type a unique descriptor. PeakT

Página 153 - Solvent Description

Section 4 User Help Reference4-13the run data by clicking the Save button, abort the run by clicking the Rewind button, or resume the run by clicking

Página 154

CombiFlash Torrent® User Manual4-14When an optional fraction collector or fractionation valve is not connected to the system, peak isolation is still

Página 155

Section 4 User Help Reference4-154.3.2 Method EditorThe Method Editor window has several sections. The BUTTON BAR [4.3.2.1] at the top of this windo

Página 156

CombiFlash Torrent® User Manual4-16PeakTrak’s default Run Length units by changing the CONFIGURATION [4.3.10] settings.4.3.2.2 Run Settings• RediSep

Página 157 - DECLARATION OF CONFORMITY

Section 4 User Help Reference4-17Time Windows can limit the fraction collection to specific time durations of the run. To use time windows, first ent

Página 158

CombiFlash Torrent® User Manual4-18once for each gradient point that must be added to the plot area.• Delete —Click this button to enable the gradient

Página 159

Section 4 User Help Reference4-19• Insert Point — This command or button will insert a row below the selected point. • Delete Point — This command wi

Comentários a estes Manuais