Malfunctions and trouble-shooting
7 Malfunctions and trouble-shooting
Fault Possible Cause Solution
Material in the
heater does not
become warm
at all
No electricity A: Check that electricity is available
B: Check the power connection and power supp-
ly cable and replace if necessary.
The above solutions (Point A and B) may only
be performed by qualified electrical person-
nel
The temperature limiter
has shut off the fluid
heater
C: Press the reset button until the control lamp
lights.
Material heats
but does not re-
ach the desired
temperature
Heating cartridges are
defect
Contact Customer Service
Temperature limiter is
defect
Contact Customer Service
Temperature is set
incorrectly
Reset the temperature using the temperature
knob
The amount of material
passing throught the
heater is too large
Lower material flow (smaller tip size)
Add a second Fluid Heater in series to the sys-
tem
Male adaptors or
fluid hoses are
leaking
Male adaptors and/
or fluid hoses are not
tightened correctly or
damaged
Re-tighten the male adaptors and/or fluid hoses
or replace as necessary
Material does not
flow
Heat exchanger is
clogged
If the material in the heater
is not completely cured, it may be possible to re-
move it by flushing under high pressure: HP max.
450 bar (6525 psi) / LP max. 200 bar (2900 psi).
Due to the danger of explosion, the Fluid Heater
may only be flushed when completely cold.
Thoroughly flush the heat exchanger or replace if
necessary.
If the material is fully cured (especially with two-
component materials), the heat exchanger must
be replaced.
The heat exchanger may only
be replaced when the Fluid Heater is cold and
disconnected from the electrical power supply.
To remove, loosen the two mounting screws
and screw in the separating screw until the heat
exchanger has separated from main housing.
Before mounting, the cone-shaped surface inside
the heat exchanger must be coated completely
with copper paste (
Order No. 0000233).