SPERIAN
SURVIVAIR Opti-Fit
S-Series
Full Facepiece Air Purifying Respirator
Operation and Maintenance Manual
WARNING
DO NOT USE this respirator until you completely read and understand
this instruction manual. You are required to inspect the respirator pri-
or to putting it into eld service. Please refer to the inspection proce-
dures in this manual. Failure to comply with this warning may result in
personal injury, illness, or death.
NIOSH APPROVED—SEE SEPARATE APPROVAL LABEL
AN ISO 9001
REGISTERED
COMPANY
©
Copyright July 2008 All Rights Reserved
SPERIAN Respiratory Protection USA, LLC
P/N 622094 Rev. G 03/09
SPERIAN Respiratory Protection USA, LLC
3001 South Susan St., Santa Ana, CA 92704
Toll-Free 888.APR.SCBA or 714.545.0410
Fax 714.850.0299
www.sperianprotection.com
Vista de página 0
1 2 3 4 5 6 ... 21 22

Resumo do Conteúdo

Página 1 - S-Series

SPERIANSURVIVAIR Opti-Fit™S-SeriesFull Facepiece Air Purifying RespiratorOperation and Maintenance ManualWARNINGDO NOT USE this respirator until you c

Página 2 - Table of Contents

101051 Combination Organic Vapors and P1001052 Combination Acid Gases and P1001053 Combination Organic Vapors, Acid Gases, and P1001054 Combination Am

Página 3

11Acroline Carbonyls Hydrogen Selenide OzoneAniline Cyanogen Methanol PhosgeneArsine Dimethylaniline PhosphineBoron Hydrides Dimethyl Sulfate Methylen

Página 4

12WARNINGFilters improperly used or improperly assembled to the facepiece could cause leakage, which could lead to personal injury, illness, or dea

Página 5

13NOTEWhen properly adjusted, the headstrap hub should be centered on the back of your head, and the lower straps should be below your ears.OPTI-FIT F

Página 6 - WARNING—Continued

14VIII. HOW TO USE THE RESPIRATORTo receive the maximum protection available from your respirator, you must read, understand, and follow all the Warni

Página 7 - IV. PARTS LIST (See Figure 1)

15replaced whenever they are damaged, soiled, contaminated with water, or as soon as they are too difcult to breathe through. Sperian recommends, due

Página 8

16CAUTIONDo not use solvent type cleaners to clean any part of the respirator.NOTESilicone and rubber parts of the facepiece may be cleaned between wa

Página 9

17WARNING• The failure to comply with this warning may lead to personal injury, ill-ness, or death.XIV. REPAIR (See the Repair Table)Repair by the use

Página 10

18XVIII. ADDITIONAL INFORMATIONIf you need assistance or additional information on any SPERIAN product, consult your local distributor or contact:SPER

Página 11

19XX. INSPECTION TABLEIF ANY OF THE DEFECTS LISTED ARE FOUND, HAVE THE RESPIRATOR REPAIRED BEFORE USE.COMPONENT LOOK FORFACEPIECE LENS 1. Nicks, scr

Página 12

2Table of ContentsNIOSH CAUTIONS AND LIMITATIONS ... 3I. INTRODUCTION... 3II. SAFETY PRECA

Página 13

20XXI. REPAIR TABLECOMPONENT INSTRUCTIONSHEADSTRAP REPLACE-MENT1. Remove the old headstrap from the facepiece, noting the routing of the straps.2. Ins

Página 14

21XXI. REPAIR TABLE (Continued)COMPONENT INSTRUCTIONSLENS REPLACEMENT 1. Remove any cartridges and/or lters from the con-nectors.2. Use a 5/32 inch A

Página 15

22www.sperianprotection.com

Página 16

3NIOSH APPROVAL CAUTIONS AND LIMITIONSA - Not for use in atmospheres containing less than 19.5 percent oxygen.B - Not for use in atmospheres immediate

Página 17

4NOTEMaintenance or operating procedures and techniques or information consid-ered important enough to emphasize.III. DESCRIPTIONThe SURVIVAIR Opti-Fi

Página 18

5WARNING—Continued• Do not use this respirator at ambient temperatures above 130°F (55°C).• Do not use this respirator where environmental conditions

Página 19

6WARNING—Continuedsensitizers. Use positive pressure supplied air respirators to provide better protection from these chemicals. Do not use

Página 20

7IV. PARTS LIST (See Figure 1)ITEM QTY P/N DESCRIPTION1a 1 702009 Headstrap, TPE1b 1 702089 Headnet, Mesh, Opti-Fit2 1 962157 Small Skirt, Silicone1 9

Página 21

8Note: Quantities in parentheses are for headnet conguration only.Optional Accessories702019 Peel-away Lens Cover, Tinted (25)702028 Peel-away Lens C

Página 22

9Table 1. Cartridges and Filters (S-Series)(See NIOSH Approval Label for Specific Contaminants)MODEL FILTERS1050 P1001060 Filter Pad, N951070 Filter P

Comentários a estes Manuais

Sem comentários